Home > Runtime Error > Dos Program Runtime Error 200

Dos Program Runtime Error 200

Contents

It is possible to make a batch run TPPATCH on all executables on the hard disk, because TPPATCH does a bunch of tests with every file, so not a single wrong As of Jan 2000, we released ver 1.6, which also recognises this similar code, and patches it accordingly. I supposed the program is a Borland Pascal application since that suffers a runtime 200 failure due to too fast processing speed (over 200 MHz). First of all you can disable the delay-routine completely. his comment is here

TPPATCH does fix a bug appearing in all programs that have been written using Turbo Pascal when such a program is run on a Pentium Pro 200MHz or a faster computer. It is known as the CRT unit issue and can be fixed by applying a patch to the effected application. tpbug.zip new TPL files not available for download here because of potential copyright problems File contains exactly the same files CRT.ASM, CRT.PAS and CRT.TPU (included in TURBO.TPL) as BPPATCH.ZIP. PatchCRT does not include any de-compression code, and therefore will not repair compressed EXE files.

Runtime Error 200 Pascal

Technical details: A patched program will test if the computer is too fast. Once you have sucessfully uncompressed a compressed .EXE file, you should then be able to run PatchCRT on it to remove the RTE200 bug. ctbppat will then allow you to patch the code with the new divisor (the default is 255, but by using the "/BRUTE=XXXX" switch, where XXXX is the divisor in HEX, you Contact John Dailey Software with suggestions, comments or questions.

Welcome to denMike's tiny page! With this bugfix you can patch all files that have been compiled with Turbo Pascal, for example Crosspoint. Created using The Semware Editor. Runtime Error 201 Some programs require correct timing, for those this patch may do more harm than help!

The following two NOT instructions negate the value of the counter and divide it then by 55. (37h=55d) The result is saved in a variable (here [005C]) und is used by Runtime Error 200 Patch I find this a bit suspicious and are very uncomfortable with using the new file as long as I don't know precisely what's going on here. Last change: 22-Aug-1998 Collection The nice thing about UNP is it runs well under Windows. http://www.vogons.org/viewtopic.php?t=93 Download CRTFix 1.16 A CRT bug patching program.

We apologise if this is a source of confusion. Runtime Error 100 cs:0081 F7D0 not ax cs:0083 F7D2 not dx cs:0085 B93700 mov cx,0037 cs:0088 3BD1 cmp dx,cx cs:008A 7205 jb 0091 cs:008C B8FFFF mov ax,FFFF cs:008F EB02 jmp 0093 cs:0091 F7F1 div This program corrects the problem by patching your executable. Here are the two apps I use for patching EXE files that are plagued with the infamous Runtime Error 200 (divide by zero).

Runtime Error 200 Patch

There are several programs that allow this. check over here The symptom is a Divide-by-Zero error message when the app is run on a fast CPU, or a Divide Overflow error message, or a Runtime Error 200 message, or similar. Runtime Error 200 Pascal additional feature: disables all other interrupts during delay initialization to make initialization more reliable. Runtime Error 2001 I have used this tool to uncompress several .EXE's which UNP was unable to do.

PLEASE NOTE: This is NOT a perfect solution. this content My second choice would be CUP386, but this works best in a plain DOS environment without any extended memory manager (including himem.sys or emm386.sys) installed. Skip to content Ignore Learn more Please note that GitHub no longer supports old versions of Firefox. Knowledgebase FAQ Y2K Information Contact Us Other Support Search Site Map | FAQ Runtime error #200 occurs whenever any John Dailey Software products are ran. Runtime Error 2004

Steps: Run the TP75.EXE and allow loading into TSR memory. Furthermore on even faster computers than today this patch will fail and the run time error will re-appear even with the patch applied. Turbo Pascal had a timing bug that would cause its complied programs to crash when they were operating on machines running at 200Mhz or faster. weblink Yes No I don't know View Results Poll Finishes In 6 Days.Discuss in The LoungePoll History About Us | Advertising Info | Privacy Policy | Terms Of Use and Sale |

It supports MMX and 3DNow!.TO RUN: "ctbppat [filename.ext] /mon"PROGRAMMERS!The file ftp://ftp.heise.de/pub/ct/ctsi/bppatch.zip contains a modified version of the CRT unit, which should be good for clock speeds up to 300GHz.Enjoy!Andreas [email protected] Englishized Tp7p5fix If you have Turbo Pascal only, it's a bit more complicated. ctbppat v1.2 © Andreas Stiller [April 2000]ctbppat fixes programs coded in Borland Pascal that cause runtime error 200 on systems with clock speeds of over 200MHz.

Turbo Pascal instead of Borland Pascal).

Use: patch your TPL files, then recompile your pascal sources. Note: This is a new program version that will work also if you have only TURBO.TPL, no TPP.TPL (i.e. Report • #1 IVO January 28, 2011 at 01:38:28 Please, specify better which program you are talking about and the operating system you are running , i.e. Freedos Runtime Error 200 Some are to patch the CRT unit in your compiler (so you can produce programs free of the problem) and others are programs to patch executable programs that have the problem

Borland Pascal Runtime Error 200 problem There is a problem in the CRT unit of Borland Pascal 7 and Turbo Pascal (for DOS) which manifests itself as... Borland (now Inprise) has no officially-supported fix for this but several unofficial fixes have appeared on various Pascal programming forums and newsgroups. Home EleBBS FAQ How to fix a Run Time Error 200 Run Time Error 200 (Divide by Zero) is usually caused by a bug check over here But I haven't tested it with TP6.

Remove the Delay initialization code (lines 94 to 107, both inclusive). 3. Which is another way of saying - TEST your app carefully, if PatchCRT patches it !!. However, by running "ctbppat [filename.ext] /brute", one can force the program to search for the incorrect code but WITHOUT further analysis (which prevents error checking and will then allow the faulty Note-2: We think there is some other software product out there with the same name (PatchCRT).

Note: we've seen a few EXE files with the 200 error, but which PatchCRT, up to ver 1.5, would not adjust. If you need a delay routine you can use the one found in this document, you can create your own, or you can find another one somewhere on the web. There is no material that is knowingly illegal here. Warnings: the program patch is only suitable for programs that do not require precise timing the included TPL files were created based on the Run Time Library of Turbo Pascal 7.0

Use: In your program sources include this unit first, crt second, then all other units and then recompile your programs. Runtime Error 200 Causes The Runtime Error 200 problem is generated in the initialization routine’s internal workings. To patch software without having the source of it, you can apply better methods, for example replacing Delay() if you have the runtime sources, and a unit has been posted in If no it proceeds with calculating the delay factor as usual.

http://www.brain.uni-freiburg.de/~klaus/pascal/runerr200/ ...but as is often the way with sites at universities, Klaus' directories are gone now. Snover l33t++ Posts: 5207Joined: 2002-6-30 @ 04:47 Top Re: Fix "Error 200" (Divide by zero) - by Snover and Stiletto (updated!) by eL_PuSHeR » 2005-4-13 @ 20:13 I hope Snover This procedure does also work with applications compiled for the protected mode. Ceterum censeo Microsoft esse delendam.

If you'll have a gigahertz-cpu in some years, you'll get the runtime error again, so if you don't use the delay-routine at all, you might want to remove it completely: Programmers Anyway, I would like to make a minor update. All rights reserved. The first procedure (here it is on CS:0087) detects how long the cpu can decrease a counter within a time of 55ms.

Report • #3 IVO January 31, 2011 at 05:51:50 Hmm...