In my case in the msbuild script. What is fungibility and why does it matters? Reply With Quote 27-Jan-2009,06:23 AM #7 turnje View Profile View Forum Posts Visitor Join Date Aug 2007 Posts 5 BC3 Error Handling Hi Aaron Any news on when DOS batchmode error As described here http://forum.sysinternals.com/psexec-target-cmd-returns-error-code-9009_topic18945.html The hint here is that you try the deployment using psexec from pstools (http://technet.microsoft.com/en-us/sysinternals/bb896649.aspx) and check if you get the same 9009 result. his comment is here

I will do the others tomorrow morning when I am back in the office and report my findings. You have to code for halting on error. Thanks Sudhakar 0 Question by:sudhakar_koundinya Facebook Twitter LinkedIn Google LVL 15 Best Solution bylakshman_ce Error code 9009 means your .bat file was not found. Other answers mentioned missing files (or misnamed/improperly referenced-by-name files)--but the root cause was lack of disk space.

Error Code 9009 Voicemail

This will prevent # server applications that expect to make use of the system # default credentials # from accepting SSL connections. and what solution for that? Thanks Sudhakar 0 Write Comment First Name Please enter a first name Last Name Please enter a last name Email We will never share this with anyone. Application use Command line arguments, I removed them and then added them back.

Why aren't Muggles extinct? If you use this, then of course setup.exe must sit in the same directory as the script. Color replacement tool changes to grey (instead of white). Dos Beep Codes Saffron and coloration - is there a way to know why it gave the wrong color?

I removed that and it is fixed. –Pabitra Dash Dec 10 '15 at 9:25 add a comment| up vote 6 down vote I caused this error to happen when I redacted Error Code 9009 Visual Voicemail Thanks Reply With Quote 27-Jan-2009,09:52 AM #8 Aaron View Profile View Forum Posts Team Scooter Join Date Oct 2007 Location Madison, WI Posts 10,015 It is currently an open entry. share|improve this answer answered Aug 30 '13 at 13:19 Philip 1085 add a comment| up vote 3 down vote My exact error was The command "iscc /DConfigurationName=Debug "C:\Projects\Blahblahblah\setup.iss"" exited with code A very helpful feature is the built-in DOS commands like ECHO, IF, and SET will preserve the existing value of %ERRORLEVEL%.

however, once I declared a variable for the filename I was searching for in my For loop the error went away... Unix Error Codes Hot Network Questions Retrieving values() from a Map of Sets in SOQL query What are the drawbacks of the US making tactical first use of nuclear weapons against terrorist sites? Computer Hope Forum Main pageFree helpTipsDictionaryForumLinksContact Welcome, Guest. Thanks again! –AWT Apr 16 '14 at 15:41 add a comment| up vote -1 down vote I too kept getting the 9009 error code...

Error Code 9009 Visual Voicemail

I will read the post you gave me and hopefully it will list what ports I need to open which I will do in the morning.   Hi Adam, I looked http://www.febooti.com/products/automation-workshop/online-help/events/run-dos-cmd-command/exit-codes/ Bill Marked as answer by IamMredMicrosoft employee, Owner Tuesday, March 15, 2011 4:31 AM Thursday, March 10, 2011 6:23 PM Reply | Quote Moderator 0 Sign in to vote The error Error Code 9009 Voicemail share|improve this answer answered May 4 '11 at 8:06 hakksor 6611613 add a comment| up vote 7 down vote I have had the error 9009 when my post build event script Exit Code 9009 Permalink 0 Raiden Knightlore November 19, 2012 19:51 Hi TOF, I know our desktop machines have the windows firewall disabled but we do have a firewall on our MPLS line which

Would you like to answer one of these unanswered questions instead? this content I remote accessed to my office and changed some firewall settings but it didn't make any difference to the external machine I still got the 9009? I also recommend documenting your possible return codes with easy to read SET statements at the top of your script file, like this: SET /A ERROR_HELP_SCREEN=1 SET /A ERROR_FILE_NOT_FOUND=2 Note that The source code is different from the original version.” What does this mean?120Command copy exited with code 4 when building - Visual Studio restart solves it11Visual Studio Post Build Event MT.exe Dos Error Codes List

asked 2 years ago viewed 9088 times active 1 year ago Linked 0 Batch file - check if command is avilable Related 5Why does cmd.exe have different errorlevel behavior on a But in my case it was also intermittent. Why sleep? weblink I think the post build command is launched using the output directory as working directory, so if your .bat file is located in the project directory, you have to use the

To execute a follow-on command after sucess, we use the && operator: SomeCommand.exe && ECHO SomeCommand.exe succeeded! Windows Error Codes Why did the One Ring betray Isildur? After the error, the errorlevel value is: 1 After the resetErrorLevel.bat, the errorlevel value is 0 dos/errorlevel.txt · Last modified: 2015/04/24 14:43 by gerardnico Dos (Win32 Shell Scripting) and Utilities 69

Remember, this is duct tape programming.

This way we can eliminate if the problem is within PDQ Deploy or somewhere else. Is there a way to view and/or calculate the value of all utxo's? 2048-like array shift What would happen if I created an account called 'root' Incorrect method to find a Does BComp.exe not return DOS error codes for fatal error?? Linux Error Codes net helpmsg 9009 > DNS server not authoritative for zone.

Sadly, even skilled Windows programmers overlook the importance of return codes. English equivalent of the Portuguese phrase: "this person's mood changes according to the moon" Can I restore my wallet with the mnemonic seed even if the seed words are changed in Print Pages: [1] Go Up « previous next » Computer Hope » Microsoft » Microsoft DOS » If exists errorlevel 9009 not expected Old Forum Search | Forum Rules Copyright check over here And, no, I'm not Steve Jansen the British jazz drummer, though that does sound like a sweet career.

I've got compiler errors for projects that have commands in PreBuild events. 'cmd' is not recognized as an internal or external command, operable program or batch file. Please login or register.Did you miss your activation email? 1 Hour 1 Day 1 Week 1 Month Forever Login with username, password and session length Forum only search News: Home When I look this error code up I get: Program is not recognized as an internal or external command, operable program or batch file. BC v4.0.7 build 19761 ŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻŻ Reply With Quote 12-Aug-2008,02:57 AM #3 turnje View Profile View Forum Posts Visitor Join Date Aug 2007 Posts 5 Thanks Michael, but what about the "Fatal

Sometimes copying the xcopy command from the web when it's multi-line and pasting it into VS will cause a problem. You may have to register before you can post: click the register link above to proceed. The scripting engine will now return the following exit codes: 0: Script successful (no fatal errors). The output for 9009 is: # for decimal 9009 / hex 0x2331 : MSG_DIR_BAD_COMMAND_OR_FILE cmdmsg.h # '%1' is not recognized as an internal or external command, # operable program or batch

share|improve this answer answered Jul 11 '14 at 0:41 ErikE 25.6k773122 add a comment| up vote 1 down vote This is pretty basic, I had this problem, and embarrassing simple fail. Try looking at the Build log (BuildLog.htm in your debug / release directory), and also check for any .InstallLog or .InstallState files and check them to see if they have any share|improve this answer answered Aug 13 '10 at 5:05 NileshChauhan 3,74221839 7 +1 - This is exactly the problem I was having. For example: %~dp0setup.exe (%~dp0 will expand to the drive and path of the currently running script).

It is back after some remotely related issue I am yet to discover.